HOME  >>  PARTS & REPAIR  >>   EMISSIONS SOLUTIONS  >>  Electronic Packing Vent Monitor

ePV Monitor ePV
ELECTRONIC PACKING VENT MONITOR

Analyze your gas compressor packing cases




epv logo
ELECTRONIC PACKING VENT MONITOR
For compressor packing case vent flow analysis


ePV™ is a vent flow analysis tool specifically designed to monitor gas compressor packing cases. The ePV can be permanently mounted or used as a portable device to meet the EPA Greenhouse Gases Reporting Rule Subpart "W" requirements for emissions monitoring.

The ePV™ utilizes proven thermal-dispersion flow measurement technology with equal mass sensing to achieve outstanding sensitivity and repeatability. The instrument’s wetted parts are superior corrosion-resistant 316L stainless steel with Hastelloy-C sensor tips. The sensor element has no moving parts to foul, clog or maintain which ensures continuous reliability and no maintenance costs. There are no cavities, orifices or dead-legs to trap or contaminate samples which preserves sample integrity and faster system sampling times.

ePV™ electronics are packaged in a rugged, fully-sealed, aluminum housing which provides exceptional protection and long-life under all process conditions.

A 4-20mA output can be assigned to flow rate or temperature. The ePV™ unit can be programmed by the sensor push buttons or through the RS232 connection with the provided software.
 No moving parts, non-clogging
 Handles gases and liquids
 For use in tubing & piping up to 6" diameter
 Superior low flow sensing (0-100 FPS)
 Single configuration meets all flow ranges
 Outputs include both:
4-20 mA Analog Output
Serial RS232C I/O
10 LED Array on sensor face
 No cavities or dead-legs
 Simple, screw-in installation
 Lowest cost solution for end-users and system integrators
 Self-contained unit
 Does not require calibration in the field

CONTACT US
5440 Alder Dr.
Houston, TX 77081
Phone
800-TRY-CECO
800-879-2326
713-664-7333
Fax
713-664-6444
Email
epvinfo@ceconet.com
www.tryceco.com

® CECO is a registered trademark of Compressor Engineering Corporation.
© 2011 Compressor Engineering Corporation Form 2102 9/11
INSTRUMENT
MEDIA COMPATIBILITY:
All gases and liquids compatible with 316 stainless steel
PROCESS CONNECTION:
• Insertable 1/2" NPT
• Tube tee 1/4", 3/8" and 1/2" tubing
ACCURACY:
± 1% of reading, ± 0.5% of full scale ± 0.05 SFPS
All calibrations on NIST traceable flow stands
REPEATABILITY:
± 0.5% of reading
FLOW RANGE:
From 0 to 100 ft/sec velocity; flow range depends on pipe or tube tee area
OPERATING PRESSURE:
Tube tee ePV: 500 psig
Insertable ePV with compression fitting:
• 150 psig Teflon ferrule
• 500 psig Stainless steel ferrule
OPERATING TEMPERATURE:
Standard: - 40°F to 250°F
MATERIALS OF CONSTRUCTION:
(Wetted parts) 316L stainless steel with Hastelloy C-22 thermowells
TRANSMITTER/ELECTRONICS
ENCLOSURE:
NEMA 4X, anodized aluminum
OPERATING TEMPERATURE:
-40°F to 160°F
OUTPUT SIGNALS
• 4-20 mA (500 Ω max. load) User scalable, general purpose, output proportional flow rate for trend monitoring
• RS232C Input/Output Connection
• 10 LED Array
INPUT POWER:
24 Vdc (21.5 Vdc to 30 Vdc); maximum 2.5 watts
AGENCY APPROVALS
FM & FMC/ CE MARK:
Class I, Division 2, Groups A, B, C & D
Class II, Division 2, Groups E, F & G
Class III, T4 @ Ta = 71°C Type 4X
NEMA ENCLOSURE:
Nonincendive




Houston, Texas